FANUC AC Serial Spindle A06B-6062, A06B-6063, A06B-6064 Alarms and Error Codes
The following alarm codes pertain to the FANUC A06B-6062, A06B-6063, A06B-6064 series. Knowing your error code could help us provide you with the fast and precise evaluation for repair or exchange services.
Alarm Code | Type |
---|---|
A display | Program ROM abnormality. |
01 | Motor Overheat. |
02 | Excessive Speed deviation. |
03 | DC Link section fuse blown. |
04 | Input fuse blown / Input power open phase. |
05 | Control Power Supply Fuse Blown. |
07 | Excessive Speed. |
08 | High input voltage. |
09 | Excessive load on main circuit section. |
10 | Low input voltage. |
11 | Over-voltage in DC link section. |
12 | Over current in DC link Section. |
13 | CPU internal data memory abnormality. |
15 | Spindle switch/output switch alarm. |
16 | RAM abnormality. |
18 | Program ROM sum check error. |
19 | Excessive U Phase current detection circuit offset. |
20 | Excessive U Phase current detection circuit offset. |
24 | Serial transfer data error. |
25 | Serial data transfer stopped. |
26 | Disconnection of speed detection signal for Cs contouring control. |
27 | Position coder signal disconnection. |
28 | Disconnection of position detection signal for Cs contouring control. |
29 | Short time overload. |
30 | Input circuit overcurrent. |
31 | Speed detection signal disconnection motor restraint alarm. |
32 | Abnormality in RAM internal to LSI for serial data transfer. |
33 | Insufficient DC link section charging. |
34 | Parameter data setting beyond allowable range of values. |
35 | Excessive gear ratio data setting. |
36 | Error counter overflow. |
37 | Speed detector parameter setting error. |
39 | Alarm for indicating failure in detecting 1 rotation signal for Cs contouring control. |
40 | Alarm for indicating 1 rotation signal for Cs contouring control not detected. |
41 | Alarm for indicating failure in detecting position coder 1 rotation signal. |
42 | Alarm for indicating position coder 1 rotation signal not detected. |
43 | Alarm for indicating disconnection of position coder signal for differential speed mode. |
46 | Alarm for indicating failure in detecting position coder 1-rotation signal in thread cutting operation. |
47 | Position coder signal abnormality. |
48 | Position coder 1 rotation signal abnormality. |
49 | The converted differential speed is too high. |
50 | Excessive speed command calculation value in spindle synchronization control. |
51 | Under-voltage at DC link section. |
52 | ITP signal abnormality I. |
53 | ITP signal abnormality II. |
54 | Overload current alarm. |
55 | Power line abnormality in spindle switching/output switching. |
Request a Free Consultation