FANUC Beta I A06B-6132 Series Servo Amplifier Alarms and Error Codes
The following alarm codes (FANUC Beta I Servo Unit I/O Alarms) are for series A06B-6132. Knowing your error code could help us provide you with the fast and precise evaluation for repair or exchange services.
Request a Free Consultation
Please contact us for free consultation about any of the following error codes, or any other problems with your FANUC Beta I A06B-6132 Series units. Call 630-616-0039 or fill up a contact form.
Program or setting alarms (power supply alarms)
LED display | No. | Description of Alarm/Error |
---|---|---|
U | 000 | A parameter that requires power down has been specified. |
F | 011 | The specified feedrate is zero. |
F | 013 | The specified feedrate (maximum feedrate) is zero. |
I- | 070 | More than 32 blocks have been registered for a buffering operation. |
h | 085 | Input from the reader/punch interface or the like caused an overrun, parity, or framing error. |
h | 086 | Input from the reader/punch interface or the like includes an imput/output unit operation ready signal (DR) that is set to off. |
9 | 087 | After input from the reader/punch interface or the like stops, character input does not stop even though ten characters have been input. |
u | 090 | Reference position setting cannot be executed normally. |
u | 093 | A first to third reference position return cannot be executed because the reference position has not yet been established. |
7 | 224 | The reference position has not yet been established. |
7 | 250 | Input data 1 is invalid. |
7 | 251 | Input data 2 is invalid. |
n | 255 | Operation cannot be activated because an invalid mode is specified or because block execution is in progress. |
n | 255 | The interface switch signal (DRC) was switched during block execution. |
4 | 291 | The speed of an axial movement specified by an external pulse has exceeded the upper limit. |
7 | 292 | A checksum error for the batter powered memory was detected. |
Pulse Coder Alarms for Series A06B-6132
LED display | No. | Description of Alarm/Error |
---|---|---|
5 | 300 | A communication error (DTER) for the serial pulse coder was detected. |
5 | 301 | A communication error (CRCER) for the serial pulse coder was detected. |
5 | 302 | A communication error (STBER) for the serial pulse coder was detected. |
6 | 303 | An LED disconnection (LDAL) was detected in the serial pulse coder. |
6 | 304 | A mispulse alarm (PMAL) for the serial pulse coder was detected. |
6 | 305 | A miscount alarm (CMAL) for the serial pulse coder was detected. |
3 | 306 | The motor has overheated (OHAL). |
6 | 308 | A soft pulse alarm (SPHAL) was detected. |
11 | 319 | When the absolute pulse coder is used, the motor has not yet rotated through more than one turn after the first power up. |
2 | 350 | The battery voltage of the absolute pulse coder is low. |
1 | 351 | The battery voltage of the absolute pulse coder is low ( warning). |
Servo Alarms for Series A06B-6132
LED display | No. | Description of Alarm/Error |
---|---|---|
4 | 400 | The servo motor has overheated. |
401 | Servo amplifier ready signal (DRDY) went off. | |
403 | The cooling fans have overheated. ( hardware detection). | |
J | 404 | The regenerative discharge unit has overheated. |
n | 405 | Reference position return could not be executed correctly. |
r | 410 | The servo position error in the stop state is larger than the value specified in parameter no. 110. |
r | 411 | The servo position error during movement is larger than the value specified in parameter no. 182. |
c | 412 | An overcurrent alarm is issued. |
y | 413 | A DC link overvoltage alarm is issued. |
p | 414 | A DC Link low voltage is issued. |
A | 417 | A parameter has been specified incorrectly. |
418 | A DO alarm is issued. | |
t | 423 | The specified speed exceeds 32767000 detection units per second. |
C | 425 | The cooling fan has stopped. |
Over Travel Alarms for Series A06B-6132
LED display | Alarm Code | Description of Alarm/Error |
---|---|---|
H | 500 | The positive stroke limit has been exceeded |
H | 501 | The negative stroke limit has been exceeded |
H | 510 | The positive soft stroke limit has been exceeded |
H | 511 | The negative soft stroke limit has been exceeded |
System Alarms for Series A06B-6132
LED display | Alarm Code | Description of Alarm/Error |
---|---|---|
E | – | An error was detected in the RAM write/read test at power up. |
8 | – | An error was detected in the data collation check for the battery powered memory. |
9 | – | A data transfer alarm for the battery powered memory has been issued. |
d | – | A watchdog alarm was issued. |
b | – | A checksum alarm for the control software ROM is issued. |
– | A checksum alarm for the ROM that is built into the CPU is issued. | |
. | – | An error was detected in the control circuit. |
I/O Link Alarm for Series A06B-6132
LED display | Alarm Code | Description of Alarm/Error |
---|---|---|
L | – | A Fanuc I/O link error occured. A unit connected to the line was turned off. |
No LED Display for Series A06B-6132
LED display | Alarm Code | Description of Alarm/Error |
---|---|---|
No indicators lit | – | The control circuit is not operating normally. |